The valve is fitted in the same way as the one adjacent to it for the hot water and he hasn't touched this at all. Honeywell V4043H1056 22mm 2-port zone valves have five wires: green/yellow is Earth, blue is Neutral, brown is Live (or Line) to the motor, grey and orange are connected to the end switch and form part of a separate circuit. The Honeywell V4073A is a spring-return valve. Port A or port B can be closed by a rubber ball, though never both at the same time. The rubber ball is moved between ports A and B by an actuator shaft or spindle which is driven by the powerhead. The inlet port AB can never be closed; the ball only moves between port A and port B.

If it’s the other way round, and the 2-port valve controlling the hot water circuit is failing, it may be less obvious. The heating circuit valve may be open for long periods telling the boiler to fire. If the hot water valve is partially open, you may not run out of hot water. Autumn Statement: Workers to pay less in national insurance – but rate cuts don't offset the freezing of personal tax thresholds The wires to disconnect are the two wires which run from the motor. On earlier motorised valves, these were both joined to other wires using metal crimps encased in plastic. On more recent valves, one wire is joined with a crimp and the other is wired directly to the electrical components of the valve. Honeywell V4044C1288 22mm 3-port diverter valve. This valve is not a mid-position valve. It opens either Port A or Port B (usually heating and hot water). Apart from the few moments when it is switching between ports, Port A and Port B are not open together. Note that it is a 3-wire valve, not a 5-wire valve It will make it easier when re-fitting it (just remember which end the flex was connected or take a picture on your phone). The powerhead can only fit one way round onto the valve body but if space is tight that might not be obvious.The blue wire is the Neutral, N. The green/yellow wire is the Earth wire, E. The white wire is connected to the wire from the room thermostat which calls for heating (radiators or underfloor). The grey wire is used to drive the valve to the Water Off position, in which only the heating port A is open; it closes port B. The orange wire provides a Switched Live (Switched Line) feed to run the boiler and pump. That noise and that bump are diagnostic. They tell us that the valve has moved into the mid-position where both Heating and Hot Water ports are open. If you can make a Honeywell 3-port mid-position valve move into all three of those positions, the valve and controls appear to be wired correctly and the valve appears to be working normally. V4043H1080 is a 2 port, 1” BSP Female threaded, 6-wire, normally-closed zone valve with an auxiliary end switch Only when both white and grey wires are energised (and the valve goes to the Heating Only position) can the orange wire get its 230V supply via the valve itself. (Remember, the orange wire can also get 230V from the cylinder stat if it is calling and a hot water program is on.) In medium sized or larger properties, using a combi boiler, there may be an additional zone valve external to the boiler which allows the heating to be split into two zones.

However, if you need to replace the motor it may be easier to remove the powerhead so you can work on it in the open. Remember, on early Honeywell motorised valves (pre-1985) you can’t remove the powerhead without draining down first! On older style valves pre-1985, which do not have the replaceable head feature, the adaptor plate assembly can be used to upgrade the valves, to allow the replaceable powerhead to be used.” A normally-closed valve is closed when no power is being applied to it and needs electrical power to drive it open.

The V4073A 3-port valve never closes water flow through the valve completely. There is always an open pathway from port AB to port A or from port AB to port B or from port AB to both ports A and B at the same time. NatWest, RBS and Ulster Bank to close at least 172 branches in 2023/24 – here's the full list, plus alternatives Occasionally we come across a Honeywell motorised valve where the powerhead jams but the spindle (actuator shaft) is still free. Where this happens it is usually with the valve jammed open. If all the power to the central heating system is turned off, and the manual lever is still loose across the whole slot, the mechanism may be jammed. Thanks for your reply. I don't know much about heating / plumbing so I'm a bti concerned about taking the cover off the unit and messing around with it whilst power is live to it. Whereas the internal electrics of the 2-port valve are quite simple, the internal electrical controls of the V4073A mid-position valve are more complex.

On modern Honeywell valves, if the powerhead fails it can be removed from the valve body without draining down. However,be warned!With very old Honeywell motorised valves the powerhead could not be removed without draining the water first. NatWest, Royal Bank of Scotland (RBS) and Ulster Bank, which are all part of the NatWest Group, will now shut at least 172 of their bank branches in 2023 and 2024. The Honeywell motorised valve faults detailed above are likely to apply to most domestic Honeywell valves. V4043H1056 is a 2 port, 22mm compression, 5-wire, normally-closed zone valve with an auxiliary end switch

Write a review

It may be easier to have the valve set in the manually open position using the manual lever. (See Honeywell Motorised Valve Manual Lever, below.) Sometimes a powerhead is able to drive the valve only part way open but not far enough for the auxiliary circuit end switch to close. This valve will then not be able to tell the boiler to fire. Where two 2-port motorised valves are fitted (one for the heating circuit and one for the hot water cylinder circuit) the fault may be disguised. Even though one valve only partly opens itself and is unable to fire the boiler, the valve on the other circuit can open fully and fire the boiler. The pump then pushes heated boiler water through both the open valve and the partially open valve. In smaller properties there is usually one programmer which has two channels. One programmer channel controls the heating (radiators or underfloor) and the other programmer channel controls hot water. Where additional zone valves are used there will usually be another programmer or timer. Honeywell motorised valve construction Martin Lewis: What the Autumn Statement means for you – including wages, benefits, pensions, ISAs, national insurance and more